• Philips Intellivue MP60 Patient Monitor Medical Equipment for Hospital Used
  • Philips Intellivue MP60 Patient Monitor Medical Equipment for Hospital Used
  • Philips Intellivue MP60 Patient Monitor Medical Equipment for Hospital Used
  • Philips Intellivue MP60 Patient Monitor Medical Equipment for Hospital Used
  • Philips Intellivue MP60 Patient Monitor Medical Equipment for Hospital Used
  • Philips Intellivue MP60 Patient Monitor Medical Equipment for Hospital Used

Philips Intellivue MP60 Patient Monitor Medical Equipment for Hospital Used

Application: Medical Equipment,ICU,Hospital Device
Parameters: ECG,Temp,Resp,NIBP,SpO2
Power Consumption: < 145 W
Max Weight: <10 Kg <22.05 Lb
W X H X D: <405 X 360 X 170 mm 15.95 X 14.17 X 6.69 in
Transport Package: Standard Export Packing
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Major Parts and Keys
  • Specifications
  • Detailed Photos
  • Note
Overview

Basic Info.

Model NO.
MP60

Product Description

Philips MP60 intellivue patient monitor
Philips Intellivue MP60 Patient Monitor Medical Equipment for Hospital
 

Product Description

Philips MP60(M8005A) Patient Monitor has a 15-inch color LCD display, and the display unit can be combined with data processing. It is more powerful than previous patient monitors, and can display up to eight waveforms of patient vital signs on the screen and 12-lead ECG screen. The MP60 uses a SpeedPoint as its primary input device, and its display can be connected to the Multi-Measurement Module (MMS) and any one of the MMS extensions, as well as to the flexible module rack (M8048A).

 Philips Intellivue series plug-in measurement modules can be connected to other FMS module slots, and the corresponding functions can be used after plugging them in. Philips MP60(M8005A) Patient Monitor has two integrated slots for inserting modules, which can be inserted to measure pressure, temperature, C.O., BIS, SpO2, VueLink and IntelliBridge respectively. But only two different modules are allowed to be used together, not two modules of the same type. And it is also possible to use a dual-slot logger module in the integrated slot.
 

Major Parts and Keys
Philips Intellivue MP60 Patient Monitor Medical Equipment for Hospital Used
  1. Color coded alarm lamps
  2. Alarms Off lamp
  3. Display
  4. Model indicator
  5. SpeedPoint
  6. Part number and serial number
  7. Mounting quick-release lever(when this is pressed the monitor is not fixed on the mounting)
  8. AC power LED
  9. Error LED
  10. Power on/standby switch
  11. Power on LED

 

 

Specifications

 Environmental requirements :
The working environment of MP60 monitor should avoid vibration, dust and corrosive or explosive gas as much as possible. Environmental operating and storage conditions for the MP60 monitor must be observed. If these conditions are not met, the accuracy of the system will be affected and damage may occur.
 
Max Weight W x H x D Comments
<10 kg
<22.05 lb
<405 x 360 x 170 mm
15.95 x 14.17 x 6.69 in
without handle and speedpoint device, without options
Item Condition Range
Temperature Range Operating 0 to 35ºC (32 to 95ºF)
Non-operating --20 to 60ºC (-4 to 140ºF)
Humidity Range Operating 20 % to 85 % Relative Humidity (RH) (non condensing)
Non-operating 5 % to 85 % Relative Humidity (RH)
Altitude Range Operating 0 m to 3000 m (10000 ft)
Non-operating 0 m to 12000 m (40000 ft)


 
Detailed Photos
Philips Intellivue MP60 Patient Monitor Medical Equipment for Hospital Used
Philips Intellivue MP60 Patient Monitor Medical Equipment for Hospital Used
Philips Intellivue MP60 Patient Monitor Medical Equipment for Hospital Used

 

Note

If the Philips MP60(M8005A) Patient Monitor is used to examine the heart or the inside of the brain, please make sure that the patient monitor is connected to the equipotential grounding system.

The Philips MP60(M8005A) Patient Monitor must be grounded during operation. If there is no three-wire outlet, you must consult a professional to ensure that you can install it with a ground.

Do not use it with the Philips MP60(M8005A) Patient Monitor by trying to convert the three-wire socket into a two-wire adapter, otherwise some accidents may occur.

For safety and interference suppression purposes, each component of the Philips MP60(M8005A) Patient Monitor must be grounded individually to avoid accidents.
 

 

 

Thank you for your interest in Philips Intellivue MP60 Patient Monitor Medical Equipment for Hospital.If you are interested in our products, please feel free to contact us, we will be happy to serve you.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now