iM70 Plastic Rear Cover
iM70 Patient Monitior Rear Cover Plastic Medical Equipment Parts
The iM70 Plastic Rear Cover is the housing part of the iM70 patient monitor. Made primarily of tough and durable plastic. It is not a complete housing, but includes the left and right sides and the back of the patient monitor. There are still some hollow parts on the iM70 Plastic Rear Cover, which are responsible for different functions. For specific functions and interfaces, please see below.
Specifications
Brand |
|
Product Catrgory |
Medical Equipment Parts |
Product Type |
Rear Cover |
Application |
iM70 Patient Monitior |
Condition |
Good |
Delivery |
3-5 Working Days |
MOQ |
1 |
Side View
1. Recorder
2. Battery door: used to fix and replace the battery.
Rear View
1. Handle: Used to lift or move the monitor, convenient, comfortable and fast.
2. Tags
3. VGA output: Enable VGA video output.
4. USB ports: support USB 2.0 output. It connects approved USB devices such as USB flash drives, barcode scanners, mice and keyboards.
5. Multi-function ports: nurse call port/analog output/defibrillator sync.
Nurse Call Port: Connects the monitor to the hospital's nurse call system. If configured to do so, the alarm indication will be alerted through the nurse call system.
Analog output: The monitor outputs waveforms through the port.
Defibrillator synchronization: The monitor outputs the defibrillator synchronization signal through the port.
6. Network interface: Connect the monitor with MFM-CMS, CMS-LITE or the gateway through a standard network cable, so that the MFM-CMS or gateway and the monitor can realize two-way communication.
7. Anti-theft lock interface
8. Heat sink: adopts fanless design, dust-free, low noise, low power consumption.
9. Power connector: Used to connect the AC power cord.
10. Power cable safety latch, used to prevent the power cord from becoming loose or falling. Place the latch on the power cord and press down firmly to make sure it secures the cord.
11. Equipotential grounding terminal, if the monitor or other processing unit is used for internal examination of the heart, ensure that the room has an equipotential grounding system, and the monitor and other processing units are connected separately.
12. Speakers