Customization: | Available |
---|---|
Customized: | Non-Customized |
Display Type: | Color TFT LCD |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
G30 Patient Monitor is a patient monitor that meets the requirements of clinical medicine. It has a high-resolution 10.4-inch color TFT display, which can display up to 8 waveforms and 7-lead ECG synchronous display. It can perform ST and arrhythmia analysis, with optional dual-channel IBP and CO2 monitoring, drug dose calculation and titration table, and OxyCRG dynamic view display. It is applicable to a wide range of people, ranging from neonatal patients to adult patients. G30 Patient Monitor also has the LAN network function and external VGA interface of the UT4800 central monitoring system, making the work of medical staff more efficient and easier.
Display | |
Type | Color TFT LCD |
Size | 10.4"(26.42cm) |
Resolution | 800Hx600V Pixels |
Channels | 6 channels or 8 channels(adjustable) |
Power Supply | |
Battery | Detachable battery Maximum 1.5 hours continuous monitoring (1 battery) |
AC power requirements | 100-240VAC, 50/60Hz |
Weight & Dimensions | |
Net weight | Approx. 4.5kg |
Dimensions | 278mm (w) x167mm (d) x298mm (h) |
Parameters | |
Standard | ECG, HR, RESP, NIBP, SpO2, PR, 2×TEMP |
Optional | 2×IBP, EtCO2 |
Lead type | Standard 3-lead or 5-lead selectable |
Lead selection | I, II, III or I, II, III, aVR, aVL, aVF, V |
HR measurement range | 15bpm-300bpm |
Accuracy | ±5 bpm or ±1% whichever is greater |
Arrhythmia | 13 calls |
ST measurement range | -0.8mV - +0.8mV |
Accuracy | ±0.02mV or ±5% |
Sweep speed | 6.25mm/s ,12.5mm/s, 25mm/s, 50mm/s |
Gain selection | x1/4, x1/2, x1, x2, x4, Auto |
Pacemaker detection | Yes |
Protection | Against electrosurgical interference and defibrillation |
Measurement range | 0-100% |
Accuracy | 70%-100%, depends on sensor 0-69%, unspecified |
PR range | 30bpm-240bpm |
PR accuracy | ±2bpm or ±2%, whichever is greater |
Method | Automatic oscillometric | |
Parameters | SYS/DIA/MAP/Pulse Rate | |
Operating modes | Manual/Auto/STAT | |
Auto measure time | 1-10,15, 30, 60, 90,120,180, 240, 480 minute intervals | |
Units | mmHg/kPa | |
Cuff pressure range | Adult/Pediatric | 0-300mmHg |
Neonate | 0-150mmHg | |
Measurement and alarm range | SYS | Adult: 30mmHg-254mmHg (4kPa-33.9kPa) |
Neonate: 30mmHg-135mmHg (4kPa-18kPa) | ||
DIA | Adult: 10mmHg-220mmHg (1.3kPa-29.3kPa) | |
Neonate: 10mmHg-110mmHg (1.3kPa-14.7kPa) | ||
Accuracy | Max. Std. Deviation | 8mmHg (1.1kPa) |
Max. Mean Error | ±5mmHg (±0.7kPa) |