• Ut6000A Patient Monitor Display Au Optronics A070fw03 V. D
  • Ut6000A Patient Monitor Display Au Optronics A070fw03 V. D
  • Ut6000A Patient Monitor Display Au Optronics A070fw03 V. D
  • Ut6000A Patient Monitor Display Au Optronics A070fw03 V. D
  • Ut6000A Patient Monitor Display Au Optronics A070fw03 V. D
  • Ut6000A Patient Monitor Display Au Optronics A070fw03 V. D

Ut6000A Patient Monitor Display Au Optronics A070fw03 V. D

Product Category: Medical Parts
Product Item: Display
Model No.: A070fw03 V.D
Size: 7 Inches
Feature: display ECG, Resp, Temp, NIBP, SpO2
Transport Package: Standard Export Packing
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Trading Company
  • Overview
  • Brief Description
  • Specifications
  • More Deatils
  • Detailed Photos
Overview

Basic Info.

Model NO.
A070FW03

Product Description

UT6000A Display A070FW03
UT6000A Patient Monitor Display AU Optronics A070FW03 V.D
Brief Description

The UT6000A Display A070FW03 can display the patient's physiological signals monitored by the patient monitor, and convert them into digital data for analysis, including ECG, RESP, TEMP, NIBP, SpO2 and other physiological signals. It helps the staff understand the patient's situation more quickly and clearly, and make clinical judgments and decisions.
 

 
Specifications
Brand  
Product Category Medical Parts
Product Item Display
Model No. A070FW03 V.D
Size 7 Inches
Condition New Original / Used - Good
Warranty 90 Days
MOQ 1 Piece
Feature Diaplay the ECG,RESP,TEMP,NIBP,SpO2


 
More Deatils
The UT6000A Display A070FW03 may have the following problems during use:
Ut6000A Patient Monitor Display Au Optronics A070fw03 V. D
When the power is turned on, but the monitor screen is black:
1. It may be a bad connection between the backlight LCD board and other components, you need to make sure the connections between the cable, LCD, backlight and motherboard modules are correct;
2. It may be that the inverter is broken and needs to be replaced;
3. It may be that the LCD screen is broken, and the front cover assembly needs to be replaced;
4. It may be that the motherboard module is faulty and needs to be replaced.
It appears that the display shows a white background or shows random/distorted graphics:
1. It may be that the LCD cable is not connected correctly, you need to open the monitor and reinstall the LCD signal cable;
2. It may be that the LCD screen is faulty and the front cover assembly needs to be replaced.
3. It may be that the motherboard module is faulty and needs to be replaced.
Ut6000A Patient Monitor Display Au Optronics A070fw03 V. D

 

 
Detailed Photos
Ut6000A Patient Monitor Display Au Optronics A070fw03 V. D
Ut6000A Patient Monitor Display Au Optronics A070fw03 V. D

 




 

Thanks for your time, if you are interested in UT6000A Patient Monitor Display AU Optronics A070FW03 V.Dor have any suggestions for us, please feel free to contact us. We will reply you within 12 hours, wish you a happy life.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now