Basic Info.

Model NO.
M2741A
Color
White
Warranty
90 Days
Ship
3-5 Days
MOQ
1 PCS
Origin
United States

Product Description

                                         New and Original Philips M2741A CO2 Sensor
                                  Hospital New and Original Philips M2741A CO2 Sensor Medical Equipment
Product Description

Monitoring supplies of the lateral flow co2 sensor
Product number: m2741a
Description: lateral flow co2 sensor compatible with the entire intellivue monitor family (d.o version or later). Ms_rco2 m2741a secondary current sensor.
Use with lateral extension server philips medical instruments, m3014a, mp5, m8105a, mp2, m8102a, MMS x2, m3002a

procedure

1.  Connect the m2741a co2 sensor to the patient monitor. Connect the sample line and the lime.
Tube to sensor. Make sure the sensor is disconnected from the patient's circuit.
2.  Turn on the patient monitor.
3.  Enter the monitor service mode.
Performance assurance tests
3 tests and maintenance 89
4.  Using the sensor status provided in the m2741a serial protocol, wait for the m2741a
Sensor is heated to its operating temperature.
5.  Reset the sensor. Make sure zero gas is set up in room air
6.  Connect a gas mixture with a regulated flow of 5% co2, balance n2 to the calibration tube.
7.  Turn off the gas correction.
8.  Wait a few seconds for the gas mixture to stabilize and observe the co2 value. 

 

Brand Philips Model No. M2741A
Original United States Type Sensor
Ship 3-5 days Warranty 90 days
MOQ 1 pcs Color White

 

New and Original Philips M2741A CO2 Sensor
Note:
Make sure you follow the above steps correctly. If the sensor does not pass this check, it must be
Exchanged sensor cannot be calibrated

 
Product Details

 

New and Original Philips M2741A CO2 Sensor
New and Original Philips M2741A CO2 Sensor
New and Original Philips M2741A CO2 Sensor

 

                              If you are interested in new and original Philips M2741A CO2 Sensor, please feel free to contact us.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier