• AG Agcl Electrode Sensor Foam Pre-Gelled 40493e Ref 989803101681
  • AG Agcl Electrode Sensor Foam Pre-Gelled 40493e Ref 989803101681
  • AG Agcl Electrode Sensor Foam Pre-Gelled 40493e Ref 989803101681
  • AG Agcl Electrode Sensor Foam Pre-Gelled 40493e Ref 989803101681
  • AG Agcl Electrode Sensor Foam Pre-Gelled 40493e Ref 989803101681
  • AG Agcl Electrode Sensor Foam Pre-Gelled 40493e Ref 989803101681

AG Agcl Electrode Sensor Foam Pre-Gelled 40493e Ref 989803101681

Customized: Non-Customized
Material: Foam
Size: 54 mm (2.1′′) Diameter
Gel-Type: Wet
Shape: Round
Application: Adult
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Trading Company
  • Overview
  • Brief Description
  • Precautions
  • Specifications & Details
  • Instructions for use
  • Detailed Photos
Overview

Basic Info.

Model NO.
40493E
Category
ECG
Transport Package
Standard Export Packing

Product Description

 Ag AgCL Electrode Sensor Foam Pre-gelled 40493E REF 989803101681
 Silver/silver chloride (Ag/AgCl) sensor, foam, pre-gelled
 
Brief Description

 Ag AgCL Electrode Sensor Foam Pre-gelled 40493E REF 989803101681 is a device for OR, ER, ICU and other medical environments. The suitable crowd is only adult patients, children and neonatal patients are not allowed to use this product. Users should pay special attention to this when using it, so as not to cause unnecessary accidents, such as affecting the life and health of patients. The main function of  Ag AgCL Electrode Sensor Foam Pre-gelled is responsible for ECG detection for patients. When the patient needs to perform ECG detection, connect it to the corresponding cable and monitor, and then connect it to the monitoring site on the patient to perform ECG monitoring. It is a very effective and practical device in the healthcare environment.

 

Precautions

When performing detection, the user must ensure that the electrodes and the patient are connected correctly and in place. If the electrodes are in poor contact with the patient, the quality of the transmitted signal and the related waveform on the display will be poor, and even false alarms may occur.

When performing the test, it is important to ensure that the patient's skin is properly prepared for the test and that the gel of the electrodes is moist. Otherwise, it will lead to poor contact between the electrode and the patient, which will affect the accuracy of the detection result. So please be sure to prepare before using it.

Before using Ag AgCL Electrode Sensor Foam Pre-gelled, be sure to carefully inspect the ECG cable or patient cable for defects or visually inspect them for visible damage. If it is damaged, please stop using it immediately, otherwise it may lead to poor contact and even affect the health of patients.

 

Specifications & Details
Product Category ECG
Product Type Electrode
Material Foam
Patient Application Adult
Elecrode Size 54 mm (2.1'') diameter
Gel-Type Wet
Elecrode Shape Round
Electrode Connector Type Snap, Grabber


 

Instructions for use

Users must keep the following guidelines in mind to ensure a good connection between devices:

1. Once connected, the electrodes should not move in any way.

2. Regularly check that the electrodes are firmly attached and in full contact. If the electrode moves easily, the electrode connection is too loose and may need to be replaced.

3. Tape the wire about 3-4 inches away from the electrode with slack in the wire to prevent it from pulling on the electrode.


 

Detailed Photos
AG Agcl Electrode Sensor Foam Pre-Gelled 40493e Ref 989803101681
AG Agcl Electrode Sensor Foam Pre-Gelled 40493e Ref 989803101681
AG Agcl Electrode Sensor Foam Pre-Gelled 40493e Ref 989803101681



 

 

 Thanks for your time. If you are interest in  Ag AgCL Electrode Sensor Foam Pre-gelled 40493E REF 989803101681Please kindly contact me.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now