Overview

Basic Info.

Model NO.
LNCS TC-I 1895
SpO2 Accuracy
3.5%
Transport Package
Standard Export Packing

Product Description

M-asimo LNCS TC-I Reusable Tip Clip Sensor
M-asimo 1895 LNCS TC-I Reusable Tip Clip Sensor Earlobe
 
Brief Description

The M-asimo LNCS TC-I Reusable Tip Clip Sensor is intended for use in adult and pediatric patients > 30 kg and enables a "spot check" of arterial hemoglobin functional oxygen saturation (SpO2) and pulse rate (measured by the SpO2 sensor) "mode" or continuous non-invasive monitoring of a medical device. It is different from the finger-clip sensor, which is used by clipping the patient's earlobe. But remember not to use it on patients with pierced ears, as the measurement results will be inaccurate and may not even be able to collect the required data. But it is widely used and can be used almost everywhere, including places such as hospitals, clinics, and home environments.

 

Detailed Photos
M-Asimo 1895 Lncs Tc-I Reusable Tip Clip Sensor Earlobe
M-Asimo 1895 Lncs Tc-I Reusable Tip Clip Sensor Earlobe
M-Asimo 1895 Lncs Tc-I Reusable Tip Clip Sensor Earlobe
M-Asimo 1895 Lncs Tc-I Reusable Tip Clip Sensor Earlobe
M-Asimo 1895 Lncs Tc-I Reusable Tip Clip Sensor Earlobe


 

Note

The M-asimo LNCS TC-I Reusable Tip Clip Sensor cannot be used on patients with pierced ears. Generally speaking, during use, the measurement site of the sensor on the patient's body should be replaced at least every 4 hours. However, due to the different skin conditions and tolerance of the human body, medical staff should always pay attention to the patient's condition when using it, and adjust the position of the sensor in time according to the patient's physical condition. The M-asimo LNCS TC-I Reusable Tip Clip Sensor is only suitable for the patient's earlobe or auricle, and cannot be used in other parts, otherwise the collected data will be inaccurate.

 

Method of Use
M-Asimo 1895 Lncs Tc-I Reusable Tip Clip Sensor Earlobe
Clip the sensor to the earlobe or pinna. Adjust the lead wire so that it hangs down the patient's neck toward the body.

To remove the TC-I sensor from the patient's ear, gently press and open the ear clip, then remove.

 

 

More Deatils
Length 3ft
Weight > 30 kg
Application site earlobe
SpO2 accuracy, no motion, (70-100%) 3.5%
Pulse rate accuracy, no motion, (25-240 bpm) 3 bpm




 

Please kindly contact me, if you are interest in M-asimo 1895 LNCS TC-I Reusable Tip Clip Sensor Earlobe. Thank you for your time.